Product range Fiber patch panels

Fiber patch panel: 19-inch rack, LGX and sliding drawer

A fiber patch panel (a fiber optic patch panel) is a 19-inch rack panel where a fiber cable ends on adapters, so patch cords can be plugged, unplugged and changed. ZeroLine Connect supplies them for central offices, head ends and data rooms: rack-mount panels, sliding-drawer panels, LGX cassettes and high-density MPO panels, loaded with the adapters and pigtails you name. This is not a wall box. Wall outlets, indoor boxes and outdoor FAT distribution boxes are on the fiber termination box page.

Rack-mount panels and sliding drawers
19-inch
Typical port count on a rack panel; more in 2U–4U
12–48 / 1U
Typical fiber count on a high-density MPO panel
96–144+ / U
Adapters, UPC or APC, loaded to order
LC or SC

Specification

Fiber patch panel types

19-inch fiber patch panels: rack-mount, sliding drawers, LGX cassettes and high-density MPO panels.

Type

  • Rack-mount patch panel
  • Sliding-drawer panel
  • LGX cassette
  • High-density MPO panel
Fiber patch panel with MPO trunk cables, LC connections and an optical cassette
MPO trunks and LC connectivity
Overview
TypeWhat it isTypical densityWhere it goes
Rack-mount patch panel19-inch panel, adapters on the front, splice tray inside12–48 ports per 1U; more in 2U–4UCentral offices, data rooms, head ends
Sliding-drawer panelThe same rack panel built as a drawer that pulls outSame rack sizes as the fixed panelCentral offices, where the splice tray has to be worked on in front of the rack
LGX cassetteA cassette with adapters on its front, the package we already supply for PLC splittersSplitter cassettes 1×2–1×32; MPO-to-LC cassettes of 12 or 24 fibersDistribution hubs and rack chassis
High-density MPO panelMPO trunks land on the panel; cassettes break out to LC1U to 4U, 96 to 144+ fibers per UData-center rows between racks

Port counts are typical figures already published on our fiber termination box range (12–48 per 1U, more in 2U–4U) and our MPO cabling range (1U to 4U, 96 to 144+ fibers per U). LGX splitter ratios are the cassette range on the PLC splitter page; MPO cassette fiber counts are the cassette row on the MPO page. The offer states the panel supplied.

Fiber patch panel, termination box or ODF?
PartWhat it isThis page
Fiber patch panelOne 19-inch rack unit, or a few, of adapters for patchingYes. Rack, sliding drawer, LGX and high-density MPO
Fiber termination boxA wall outlet, an indoor box or an outdoor FAT distribution boxNo. Those are on the termination box page, including pole and wall boxes
ODF (optical distribution frame)A frame that holds many panels and cross-connects hundreds of fibers in a central officeNamed here only so it is not confused with one panel. The ODN family page lists ODF as rack-mount sliding drawers. A separate ODF page is not this one

The termination-box, distribution-box, closure and ODF split is the one already on our fiber termination box page. The ODF row there says it terminates and cross-connects hundreds of fibers in a central office.

What to specify when you order a fiber patch panel
ItemWhy it matters
Rack height1U holds the typical 12–48 adapter ports; 2U–4U hold more. High-density MPO panels are quoted as fibers per U, not as duplex ports
Fixed or sliding drawerA drawer pulls out for splicing. Our ODN range lists central-office frames as rack-mount sliding drawers
AdaptersLC or SC, UPC or APC. PON panels are usually SC/APC. Ethernet and data-centre duplex panels are usually LC/UPC
Loaded or emptyEmpty panels take your own pigtails. Loaded panels ship with adapters and 0.9 mm pigtails, in 12-colour sets, spliced or left for the site
LGX or MPO cassettesAn LGX cassette is the front-adapter package we supply for splitters. An MPO panel uses MPO-to-LC cassettes of 12 or 24 fibers, Base-8 or Base-12
LabelsPort labels to your rack plan

Options

  • 19-inch rack-mount or sliding-drawer panels, 1U to 4U
  • LC or SC adapters, APC or UPC, loaded with pigtails or empty
  • LGX cassettes, including a PLC splitter cassette where the panel is also the split
  • High-density MPO panels, 1U to 4U, with the polarity method of the site

Tests and documents with every order

  • Adapter and pigtail loss checked on loaded panels, the same check we publish for loaded boxes
  • Pigtails held to the patch-cord limits: insertion loss ≤ 0.3 dB and return loss ≥ 50 dB UPC or ≥ 60 dB APC, typical maxima per mated connector
  • Splice tray fitted where the panel is the splice point
  • Sample approval before volume

Terms

Ordering, testing and delivery

Typical terms. Your offer states the exact terms for your order.

Minimum order

One drum of cable, one reel of fiber or one carton of passive components. Mixed BOMs are welcome. Samples for evaluation typically ship in 1–3 weeks.

Lead time

Stock items 5–10 working days. Made-to-order cable typically 2–4 weeks. Large framework lots ship on the agreed rollout schedule. Fiber prices moved sharply in 2026, so every cable offer states how long its price holds next to the lead time.

Fiber and cable prices in 2026
Test reports

OTDR data for every drum of cable, insertion and return loss for every connectorised assembly, loss and uniformity reports for splitters, and our pre-shipment inspection report. Third-party pre-shipment inspection on request, at the buyer’s cost.

Labelling and packing

Drum and carton labels to your scheme: project, lot, route or rack. Export cartons, and wooden or plywood drums for cable.

Payment

T/T with 30% deposit and 70% before shipment, or L/C at sight. Rollouts can run under a framework agreement with staged lots.

Payment terms and trade finance
Delivery

FOB Wuhan or Shanghai, CIF to your port, or door delivery where available. Goods from other ZeroLine lines ship in the same consignment when that saves freight.

Shipping and compliance

Keep reading

Guides, solutions and services

FAQ

Fiber patch panels: questions buyers ask

What is a fiber patch panel?

It is a 19-inch rack panel where incoming fiber is terminated on adapters. A patch cord plugs into the front, so a link can be moved without opening a splice. Behind the adapters is either a splice tray and pigtails, or an MPO cassette that breaks a trunk out to LC. It is rack hardware. It is not a wall outlet or a pole-mounted distribution box.

What is the difference between a fiber patch panel and a fiber termination box?

A fiber patch panel mounts in a 19-inch rack: fixed, sliding drawer, LGX or high-density MPO. A fiber termination box is the wall and pole hardware: a 1–4 port outlet in the home, an indoor box in a riser, or an outdoor FAT distribution box that holds a splitter and serves drops. Both can end a cable on adapters. The mounting and the density are different, and they are different pages.

How many ports does a 1U fiber patch panel have?

On the rack-mount panels we list with termination boxes, a typical 1U holds 12 to 48 adapter ports, and 2U to 4U hold more. A high-density MPO panel is counted in fibers, not duplex ports: our MPO range lists 96 to 144 or more fibers per U, in 1U to 4U. The offer states the count for the panel quoted.

What is an LGX fiber patch panel?

LGX is a cassette with adapters on the front that slides into a rack chassis. We already supply PLC splitters in that package, from 1×2 to 1×32, for distribution hubs and rack chassis. The same chassis takes MPO-to-LC cassettes of 12 or 24 fibers. The cassette is how a panel is added or swapped without replacing the whole shelf.

Is a fiber patch panel the same as an ODF?

No. A patch panel is one shelf of adapters. An ODF, an optical distribution frame, is the frame that holds many shelves and cross-connects hundreds of fibers in a central office. Our ODN range lists ODF as rack-mount sliding drawers. This page does not specify the frame.

Get a matched quote

Quote fiber patch panels

Upload a spreadsheet or tender, or paste the list. We match every line to a qualified factory and return one priced BOM, usually within 3 to 7 working days.

What is it for?

WhatsApp